Operation Theater/ ICU EquipmentsInfusion Pump St-1000 Samtronic Brazil | Sight Pakistan


  • TOTAL VOLUME INFUSED Display, ml (TOTAL VOLUME INFUSED) 0.1-9,999

  • KVO RATE, mL/hr (TOTAL VOLUME INFUSED) 0.1-3

  • POWER NEEDED, VAC (ENERGY) 110-230V

  • Kind of battery (BATTERY) Ni-Cd/Ni-MH

  • Frequency, hz (REVOLUTIONS) 50/60

  • DIMENSIONS (HXWXD) (RISE TIME, msec) 16 x 30 x 10 (6.3 x 11.8 x 3.9)

  • WEIGHT, kg (lb) (DISPLAY) 1.5

Sale!

Price On Call

  • TOTAL VOLUME INFUSED Display, ml (TOTAL VOLUME INFUSED) 0.1-9,999
  • KVO RATE, mL/hr (TOTAL VOLUME INFUSED) 0.1-3
  • POWER NEEDED, VAC (ENERGY) 110-230V
  • Kind of battery (BATTERY) Ni-Cd/Ni-MH
  • Frequency, hz (REVOLUTIONS) 50/60
  • DIMENSIONS (HXWXD) (RISE TIME, msec) 16 x 30 x 10 (6.3 x 11.8 x 3.9)
  • WEIGHT, kg (lb) (DISPLAY) 1.5

99 in stock

Description

  • TOTAL VOLUME INFUSED Display, ml (TOTAL VOLUME INFUSED) 0.1-9,999
  • KVO RATE, mL/hr (TOTAL VOLUME INFUSED) 0.1-3
  • POWER NEEDED, VAC (ENERGY) 110-230V
  • Kind of battery (BATTERY) Ni-Cd/Ni-MH
  • Frequency, hz (REVOLUTIONS) 50/60
  • DIMENSIONS (HXWXD) (RISE TIME, msec) 16 x 30 x 10 (6.3 x 11.8 x 3.9)
  • WEIGHT, kg (lb) (DISPLAY) 1.5
  • MAX UNITS PER POLE (AUDIBLE ALARM) 4IV SET Free-flow safeguard (IV SET) Yes
  • Kind of set (IV SET) UniversalTime/date stamp (ALERTS AND SIGNALS) Yes
  • FLUID RESISTANT (TOTAL VOLUME INFUSED) Yes
  • PUMP SYSTEM (AUDIBLE ALARM) Peristaltic type
  • Low battery (EQUIPMENT ALARMS) Yes
  • Infusion terminated (ALERTS AND SIGNALS) Yes
  • Occlusion upstream (ALERTS AND SIGNALS) Yes
  • Empty battery (ALERTS AND SIGNALS) Yes
  • Depleted fluid container (ALERTS AND SIGNALS) Yes
  • Circuit failure (ALERTS AND SIGNALS) Yes
  • Pressure, psi (ALERTS AND SIGNALS) kPa
  • Flow error (ALERTS AND SIGNALS) Yes
  • Real-time display (ALERTS AND SIGNALS) Yes
  • Drop sensor (ALERTS AND SIGNALS) Yes
  • Occlusion downstream (ALERTS AND SIGNALS) Yes
  • User prompts (ALERTS AND SIGNALS) Yes
  • Set disengaged (ALERTS AND SIGNALS) Yes
  • Air in line (ALERTS AND SIGNALS) Yes
  • Door open (ALERTS AND SIGNALS) Yes
  • Alarm pause (CONFIGURATION) Yes
  • Number of channels (RECORDER) 1
  • Flow Range, mL/hr (AUDIBLE ALARM) 0.1
  • Accuracy, % (POWER NEEDED) 5
  • VTBI SELECTOR, mL (AUDIBLE ALARM) 0.1-9,999
  • OTHER ATTRIBUTES (Interference compensation) Meets requirements of EN 60601-1, EN 60601-1-2, EN 60601-2-24.
  • CE MARK (MDD) (Interference compensation) Yes

    Reviews

    There are no reviews yet.

    Be the first to review “Infusion Pump St-1000 Samtronic Brazil”

    • TOTAL VOLUME INFUSED Display, ml (TOTAL VOLUME INFUSED) 0.1-9,999
    • KVO RATE, mL/hr (TOTAL VOLUME INFUSED) 0.1-3
    • POWER NEEDED, VAC (ENERGY) 110-230V
    • Kind of battery (BATTERY) Ni-Cd/Ni-MH
    • Frequency, hz (REVOLUTIONS) 50/60
    • DIMENSIONS (HXWXD) (RISE TIME, msec) 16 x 30 x 10 (6.3 x 11.8 x 3.9)
    • WEIGHT, kg (lb) (DISPLAY) 1.5
    • MAX UNITS PER POLE (AUDIBLE ALARM) 4IV SET Free-flow safeguard (IV SET) Yes
    • Kind of set (IV SET) UniversalTime/date stamp (ALERTS AND SIGNALS) Yes
    • FLUID RESISTANT (TOTAL VOLUME INFUSED) Yes
    • PUMP SYSTEM (AUDIBLE ALARM) Peristaltic type
    • Low battery (EQUIPMENT ALARMS) Yes
    • Infusion terminated (ALERTS AND SIGNALS) Yes
    • Occlusion upstream (ALERTS AND SIGNALS) Yes
    • Empty battery (ALERTS AND SIGNALS) Yes
    • Depleted fluid container (ALERTS AND SIGNALS) Yes
    • Circuit failure (ALERTS AND SIGNALS) Yes
    • Pressure, psi (ALERTS AND SIGNALS) kPa
    • Flow error (ALERTS AND SIGNALS) Yes
    • Real-time display (ALERTS AND SIGNALS) Yes
    • Drop sensor (ALERTS AND SIGNALS) Yes
    • Occlusion downstream (ALERTS AND SIGNALS) Yes
    • User prompts (ALERTS AND SIGNALS) Yes
    • Set disengaged (ALERTS AND SIGNALS) Yes
    • Air in line (ALERTS AND SIGNALS) Yes
    • Door open (ALERTS AND SIGNALS) Yes
    • Alarm pause (CONFIGURATION) Yes
    • Number of channels (RECORDER) 1
    • Flow Range, mL/hr (AUDIBLE ALARM) 0.1
    • Accuracy, % (POWER NEEDED) 5
    • VTBI SELECTOR, mL (AUDIBLE ALARM) 0.1-9,999
    • OTHER ATTRIBUTES (Interference compensation) Meets requirements of EN 60601-1, EN 60601-1-2, EN 60601-2-24.